Eaton EMA112-10 PDU 0U Vertical 16 Outlets 1.44kW 5-15P
A vertical 0U power distribution unit with sixteen 5-15R outlets and a 5-15P input rated for 1.44 kW
- Product weight13.75
- 0U vertical design saves rack space with 36U mounting height
- Managed ePDU enables remote power monitoring and control
- 16 NEMA 5-15R outlets distribute power to multiple devices
- 44 kW maximum capacity supports essential equipment loads
- 5-15P input plug connects to standard wall receptacles
Vertical managed PDU with 16 outlets
The Eaton EMA112-10 is a zero-U vertical power distribution unit rated for 1.44 kW maximum load. It accepts a single 5-15P input plug and provides sixteen 5-15R output receptacles. The managed design allows remote monitoring and control of connected equipment.
Suited for rack rows needing dense outlet count
This unit fits 36U cabinet heights and serves IT managers who need outlet-level power visibility without horizontal space loss. Buyers requiring higher input amperage or three-phase power distribution should look at alternative models.
1.44 kW maximum power rating
The 1.44 kW limit defines the total connected load this PDU can safely support. Exceeding this threshold risks tripping the input circuit or damaging attached hardware. Verify your equipment aggregate draw stays within this bound before deployment.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $860.99
- Pricier than about 72% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Eaton |
| Model name | EMA112-10 |
| Size & build | |
| Shipping weight | 5.90 kg |
| Package size | 1971 × 1971 × 236 mm |
Questions about this item
How much heat or noise does the EMA112-10 produce when running continuously at its 1.44 kW rating?
The unit has no built-in fans, so it operates silently and adds only passive heat from the 16 loaded outlets.
What plug must my facility already provide for the EMA112-10 input?
A single NEMA 5-15P receptacle on a 12 A branch circuit is required.
Will the 16 NEMA 5-15R outlets on this PDU accept the 5-15P plugs on my existing servers?
Yes, each outlet is a standard 5-15R that mates directly with common 5-15P equipment cords.
More in Rackmount PDUs
Similar items
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
CyberPower PDU44005 Switched 1U 200-240V 20A 10ft PDU
- 1U
- 200–240 V
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Eaton EMAU06-10 Managed PDU 2U 16 Outlet 12 C13 4 C19 L6-30P 5.76 kVA
- 230 V AC
- Output Receptacles:…