We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Single-pole IEC supplementary protector rated 2 A with thermal-magnetic trip, 277/480 V AC and 48 V DC, 15 kA interrupting, DIN-rail mount, UL 1077 listed
This Eaton FAZ series supplementary protector is a 2 A, single-pole device rated for 277/480 V AC and 48 V DC. It mounts on a DIN rail and uses a toggle actuator with thermal-magnetic trip characteristics. The unit carries a maximum interrupting rating of 15 kA at 277 V AC and meets UL 1077 requirements.
Installers adding a 2 A C-curve supplementary protector to a DIN-rail assembly will find this breaker matches the required voltage and interrupting ratings. It is not for applications that demand a branch-circuit breaker listed to a different UL standard. Buyers needing a different current rating, pole count or trip curve should select another model.
The 2 A rating combined with a C-curve thermal-magnetic trip characteristic defines the overcurrent response for this supplementary protector. This specification determines whether the device will co-ordinate correctly with the downstream load and upstream protection in your circuit.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | EATON |
The thermal-magnetic trip is factory-calibrated and sealed; no user recalibration is required during the service life of this 1-pole FAZ breaker.
The breaker carries a 15 kA interrupting rating at 277 V AC, which is the highest fault-current limit specified for this device.
At its 2 A rating the breaker operates within the temperature rise limits defined by UL 1077 for supplementary protectors; no additional cooling is needed for continuous duty.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?