We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Thermal overload unit covering 4.55 to 7.4 A for NEMA sizes 0 through 8, supplied in a pack of three
The Eaton H2009B-3 thermal unit provides overload protection for NEMA size 0, 00, 1, 2, 5, 6, 7 and 8 starters. It suits Series Freedom frames G, H, J and K. The pack contains three units for multi-motor installations. It is not for buyers who need electronic trip units or different current ranges.
The thermal mechanism trips at Class 20 response to sustained overcurrent. It handles full-load currents from 4.55 to 7.4 A. No external power or control wiring is required for the protection function. The transparent housing allows visual inspection of the trip indicator.
Select this unit only when the motor nameplate current falls between 4.55 and 7.4 amperes. The NEMA starter size and frame must match the listed compatibility. Incorrect sizing will cause nuisance tripping or failed protection.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Eaton |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
Snap the unit into the overload relay base for NEMA Size 0, 00, 1, 2, 5, 6, 7, or 8 starters; the step often missed is verifying the motor full-load current falls within the 4.55 to 7.4 A range before closing the cover.
The thermal unit is a Trip Class 20 overload protector; after it trips on sustained overcurrent, the internal element is spent and the entire unit must be replaced — no user-serviceable parts inside.
The thermal trip curve calibrated for 4.55 to 7.4 A is the first limit; sustained current at or above the motor's full-load rating will cause the unit to open the circuit per its Trip Class 20 timing.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?