We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A dedicated condensing-boiler cooling fan with a 230 V single-phase motor running at 4800 rpm and drawing 5.7 A at 208 V
The Fans G3G250-GN17-01 is a new centrifugal cooling fan built specifically for condensing gas boilers. It uses an external rotor motor design that integrates the motor within the impeller for compact installation. The unit suits HVAC professionals and maintenance teams replacing OEM combustion-air blowers in compatible boiler models.
Rated for continuous operation from -20 °C to 60 °C ambient temperature with a flow-medium range of 0 °C to 60 °C. The single-phase motor runs on 230 VAC across a 208–240 VAC range at 50/60 Hz, drawing 5.7 A at 208 V. Power consumption is 1150 W at a nominal speed of 4800 rpm, with the motor position providing forced electronic cooling.
The external rotor construction ensures optimum motor cooling during extended duty cycles rather than short bursts. Speed is fully controllable via analog or serial interface for precise airflow management up to 35000 m³/h. Sturdy steel-plate construction supports durability in permanent heating-system installations where reliable combustion-air delivery is critical.
Measured against everything we stock in Radiator Fans & Boiler Parts, at today’s prices. Recalculated every night.
No published specifications for this item yet.
Connect the 1~ motor to a 208–240 VAC supply at 50/60 Hz; the step often missed is confirming the line voltage is within range before applying power, because the fan draws 5.7 A at 208 V and 1150 W.
The external-rotor motor uses forced electronic cooling, so the main upkeep is keeping the impeller and inlet free of dust and debris to maintain airflow up to 35000 m³/h.
The maximum ambient temperature of 60 °C and maximum flow-medium temperature of 60 °C are the primary limits; sustained operation above either will trigger thermal protection.
More in Radiator Fans & Boiler Parts
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?