Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Single-pole 15 A molded-case breaker rated 277/480 V AC with 14 kA interrupting capacity for GE AE lighting panels
The GE TEY115 is a molded case circuit breaker rated at 15 amps for single-phase systems. It operates at 277/480V AC and 125V DC with a standard thermal-magnetic trip unit. This bolt-on device fits GE AE lighting panels and provides a 14kA interrupting rating at 277V AC.
The breaker uses a fixed instantaneous trip set at 575 amps with a high amp thermal setting. Thermal-magnetic operation responds to sustained overloads and sudden short circuits without external power. The 125-amp frame size supports the 15-amp rating within the TEY series design for panelboard protection.
A bolt-on mounting style secures the single-pole unit directly to the panelboard bus for a stable connection. Lug terminals accept wire connections for line and load sides. The compact profile measures 5.25 inches high, 1 inch wide, and 3.06 inches deep for standard panel installations.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
Align the bolt-on feet with the panelboard mounting holes, torque the mounting bolts to spec, then insert the terminal lugs; the step most often missed is verifying the lugs are fully seated before tightening the panel cover.
The thermal-magnetic trip unit is calibrated for a 575 A instantaneous setting; after multiple high-current interruptions the calibrated elements can drift, so the entire breaker should be replaced rather than serviced.
The 14 kA AIR rating at 277 V AC is the maximum prospective short-circuit current the breaker can safely interrupt; sustained loads above 15 A will trip the thermal element long before the interrupting limit is reached.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?