Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 30 A, single-pole miniature breaker rated 120/240 V AC with a 10 kA interrupting capacity for bolt-on panel mounting
The GE THQB1130 is a single-pole miniature circuit breaker rated at 30 amps for 120/240V AC systems. It uses a bolt-on mounting style and a toggle actuator to interrupt fault currents up to 10kA. The frame size is 100A/THQ, making it suitable for lighting panels and load centres that accept this form factor.
Electricians and facility managers needing a standard 30A branch-circuit device for GE-compatible load centres will find the correct voltage and interrupting rating here. Installations requiring a two-pole breaker, a DC rating, a plug-on mounting method or a different ampere rating must select another product.
The breaker clamps conductors from 14 MCM copper up to 8 MCM, with a minimum of 12 MCM aluminium, using screw-clamp terminals. Its 3.5 in length, 1 in width and 3.3 in depth fit the designated panel space, freeing adjacent slots for other circuits while maintaining the required 10kA AIR rating at the panel's voltage.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
It is built for GE lighting panels and load centres that accept the 100 A THQ frame size and a bolt-on mounting style.
The THQB1130 carries a 10 kA interrupting rating at 120/240 V AC, so it will coordinate with a 100 A main as long as the available fault current does not exceed 10 kA.
The toggle should snap firmly to the ON position, the bolt-on feet must be fully clamped to the bus stab, and a voltage check across the load terminal and neutral should read 120 V when the circuit is energised.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?