We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 10 A Z-curve miniature circuit breaker providing single-pole protection for sensitive circuits
This single-pole miniature circuit breaker from Schneider Electric carries a 10 A rating and a Z-type tripping characteristic. It is designed to protect individual circuits in electrical distribution boards where sensitive equipment requires a low magnetic trip threshold.
The Z curve suits circuits with electronic ballasts, semiconductor devices or other loads that draw low inrush currents, so nuisance tripping is minimised. It is not intended for general-purpose lighting or motor circuits that need a higher magnetic threshold such as B or C curves, nor for applications requiring multi-pole isolation or residual-current protection.
The decisive specification is the combination of 10 A rated current, Z tripping curve and one-pole construction; together they define the exact over-current protection profile and mounting footprint required for the target circuit.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Schneider Electric |
| Product type | Circuit Breakers |
Clip the single-pole body onto a standard DIN rail until the latch clicks; the step often missed is tightening the line and load terminal screws to the specified torque so the 10 A Z-curve protection works reliably.
Periodically check terminal tightness and look for discolouration or tripping without load; the Z-curve magnetic trip at roughly 30 A means nuisance trips on high inrush loads can mask a developing fault, so test-trip annually.
The thermal element calibrated for 10 A continuous current trips first during a prolonged overload, while the Z-curve magnetic release at about 30 A only operates on short-circuit or very high inrush currents.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?