We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Three-pole miniature circuit breaker rated 50 A at 240 V AC with a 10 kA interrupting capacity for Siemens P1 panelboards
This Siemens BL-series miniature circuit breaker delivers 50 A three-phase protection at 240 V AC with a 10 kA interrupting rating. It is designed for commercial and residential load centres that require bolt-on mounting in a compatible P1 panelboard. The 125 A frame size fits standard BL bus arrangements.
The thermal-magnetic mechanism responds to sustained overloads and short-circuit faults without external power. Bolt-on mounting secures the breaker to the panel bus, reducing resistance and vibration compared with plug-in alternatives. Toggle actuation gives a clear visual indication of tripped status.
Integrated lug terminals accept conductors from 8 AWG up to 6 AWG copper or 4 AWG aluminium, simplifying field wiring. The breaker occupies three pole spaces in a Siemens P1 panelboard and requires no additional accessories for standard installation. It is not rated for DC applications.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SIEMENS |
Bolt the breaker onto the P1 panelboard bus using the bolt-on mounting style, then insert 8 AWG to 6 AWG copper or 8 AWG to 4 AWG aluminium conductors into the lug terminals and torque to the value printed on the breaker label.
After a fault trip inspect the toggle actuator and lug terminals for discolouration or damage; if the contacts are eroded or the mechanism feels loose, replace the entire breaker because the BL series frame is not field-serviceable.
The thermal element reacts first, opening the 50 A poles when current exceeds the rated value for the time defined by the B-curve, well before the 10 kA magnetic interrupting limit is tested.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?