We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Molded-case circuit breaker rated 250 A with a 22 kA interrupting capacity at 600 V AC and 500 V DC, three-pole thermal-magnetic trip
The SIEMENS FXD63B250 is a molded case circuit breaker rated for 250 A continuous current on three poles. It uses thermal-magnetic trip units with fixed instantaneous settings and a high amp trip point of 250 A. The breaker fits Sentron panelboards and SB switchboards without lugs using terminal connection lugs and free-standing mounting. It is built for commercial and industrial power distribution where standard interruption is required.
The breaker carries a maximum AIR rating of 22 kA at 600 V AC, which defines the highest prospective fault current it can safely interrupt on three-phase AC supplies. For DC circuits the rating is 500 V DC with the same frame. Installations with available fault current above 22 kA at 600 V AC need a higher-rated device. The fixed instantaneous trip cannot be adjusted to coordinate with downstream breakers beyond the published curve.
Both low and high amp trip settings are fixed at 250 A, so the breaker cannot be field-adjusted for different load profiles or selective coordination schemes. Choose this model only when the design calls for a 250 A frame with non-adjustable thermal-magnetic protection on three phases. Buyers who need adjustable trip settings or a different frame size must select another breaker.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SIEMENS |
This breaker has a fixed 250 A frame and identical high and low trip settings of 250 A, so it only fits applications that require that exact rating.
It is the maximum interrupting capacity — the breaker can safely clear a fault current up to 22 kA on a 600 V AC system without damage.
Yes, the thermal-magnetic trip operates at 600 V AC and 500 V DC, and the breaker carries a 22 kA AIR rating at 600 V AC.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?