Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Protects single-phase 120/240 V AC circuits up to 30 A with a 10 kA interrupting rating in a plug-in QO frame
This SQUARE D QO130 is a miniature circuit breaker rated at 30 A for 120/240 V AC single-phase circuits. It mounts by plugging directly into QO-series load centres and NQ panelboards. The paddle actuator gives clear on-off indication. It suits residential and light-commercial branch circuits that require standard protection.
The breaker carries a maximum AIR rating of 10 kA at 120/240 V AC, limiting let-through energy during a fault. Pressure-plate terminals accept solid or stranded conductors without special tools. At 48 V DC it provides the same single-pole protection. Normal operation adds negligible heat to the panel interior.
The device shares the 100 A frame size of the QO range, measuring 3 in long, .8 in wide and 2.9 in deep. It is not designed for panels outside the QO or NQ series. Installers needing multi-pole or higher-amperage protection should select a different QO model. Sustained loads at 30 A remain within the breaker’s continuous rating.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SQUARE D |
Align the plug-in base with the panel bus, press firmly until it seats fully, then verify the paddle actuator moves freely; the step often missed is confirming the pressure-plate terminals are tightened on the circuit conductors.
The breaker itself requires no scheduled maintenance; replace it only if it trips repeatedly without overload, shows physical damage, or fails to reset after a verified fault condition.
The 30 A thermal trip curve opens the circuit when current exceeds the rated value continuously; the 10 kA interrupting rating at 120/240 V AC is the short-circuit limit, not a sustained-load limit.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?