Tripp Lite SMART3000NET 3000 VA 2400 W UPS
Line-interactive UPS delivers 3000 VA and 2400 W with eight outlets, RS-232 management and 480 J surge suppression
- AC input voltage120 V
- Input line frequency60 Hz +/- 3 Hz
- Volt-ampere rating3000 VA
- Power rating2400 W
- Voltage output120Vac +/- 5%
- Power outlets8
- 3000 VA / 2400 W capacity protects critical equipment
- Eight NEMA outlets support multiple servers and peripherals
- Line-interactive topology corrects brownouts and overvoltages without battery drain
- RS-232 port enables automated shutdown via included management software
- 480-joule surge suppression plus RJ-11 protection shields data lines
Built for server rooms and network closets
The Tripp Lite SMART3000NET is a line-interactive UPS rated at 3000 VA and 2400 watts, designed to keep rack-mounted servers, switches and storage arrays running through outages and voltage fluctuations. Eight NEMA 5-15/5-20 outlets distribute conditioned power, while an RS-232 port enables integration with management software for automated shutdown scripts. RJ-11 data-line protection shields modem, fax or DSL connections from surges.
Thermals and power behaviour
Line-interactive topology corrects brownouts and overvoltages without engaging the battery, so the unit runs quietly and efficiently during normal mains conditions. The internal battery recharges to 90 percent in two to four hours after a discharge event. Surge suppression is rated at 480 joules, and the chassis meets UL 1778, cUL, FCC Class A and NOM approvals for safe continuous operation.
Runtime at your load
At full 3000 VA load the battery provides seven minutes of backup; at half load (1500 VA) it extends to 23 minutes. Adding a single BP24V33 external pack raises those figures to 20 minutes and 53 minutes respectively. Buyers who need longer runtime without extra battery modules should look elsewhere.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $1,296.99
- Pricier than about 60% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | TRIPP LITE |
| Model name | SMART3000NET |
| Ports & slots | |
| Communication ports | RS-232 |
| Protected data lines | RJ-11 Modem/Fax/DSL protection |
| Power | |
| AC input voltage | 120 V |
| Input line frequency | 60 Hz +/- 3 Hz |
| Volt-ampere rating | 3000 VA |
| Power rating | 2400 W |
| Voltage output | 120Vac +/- 5% |
| Power outlets | 8 |
| Runtime on battery | Full load runtime: 7 minutes (3000 VA), add 1 BP24V33 for 20 minutes Half load runtime: 23 minutes (1500 VA), add 1 BP24V33 for 53 minutes |
| Battery charge time | 2-4 hour(s) to 90% |
| Surge protection rating | 480 Joules |
| Size & build | |
| Product dimensions | 17 in × 9 in × 12.5 in |
| Product weight | 89 lb (40.4 kg) |
| Shipping weight | 44.32 kg |
| Package size | 559 × 413 × 318 mm |
| Environment & compliance | |
| Regulatory approvals | UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico) |
| Software | |
| Control software | YES |
Other versions of this model
5 more in the same range
Questions about this item
How do I connect the L5-30P plug and where do people trip up?
The unit ships with a NEMA L5-30P input cord that requires a dedicated 30 A circuit; the common mistake is plugging it into a standard 15 A or 20 A receptacle instead of having an electrician install the correct outlet.
Which battery module extends runtime and how often should the internal pack be swapped?
Adding one BP24V33 external battery pack raises full-load runtime to 20 minutes and half-load to 53 minutes; plan to replace the internal sealed lead-acid batteries every three to five years.
At what load does the 7-minute full-load limit appear first during a prolonged outage?
At the full 3000 VA / 2400 W rating the battery lasts only 7 minutes, so sustained draws near that level will hit the runtime ceiling before any thermal or overload protection engages.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
APC Smart-UPS X SMX1500RM2UCNC 1440 VA 1350W 2U UPS
- 120 V
- 75–154 V Adjustable…
Tripp Lite SMART2200RMXLN 1950VA 1950W 120V UPS 7 Outlets 2U Rack/Tower
- 120 V
- NEMA 5-20P
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P
Middle Atlantic UPX-1500R-2 1500VA 1350W 8x NEMA 5-15R UPS
- 1500 VA
- 1350 W