We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv Liebert AL6B0NHVGNNXLKB UPS 10kVA/9kW 208/120V 8min runtime

SKU CH-K260-FF2A8 MPN AL6B0NHVGNNXLKB

Lithium-ion online UPS delivers 10kVA/9kW at 208/120V with eight-minute full-load runtime and hot-swappable modules

  • Voltage version208 V
  • AC input voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input line frequency40 Hz to 70 Hz auto-sensing
  • Power input4-Wire (L-L-N-G)
  • Volt-ampere rating10kVA
  • Power rating9 kW
  • Double-conversion online topology protects critical loads from power anomalies
  • 10 kVA / 9 kW capacity supports dense IT equipment racks
  • Hot-swappable power, battery and control modules enable maintenance without load interruption
  • Lithium-ion battery delivers 8 minutes at full load and 18 minutes at half load
  • Wide 200–240 VAC input range with 40–70 Hz auto-sensing suits global deployments

Three-Phase Double-Conversion UPS

The Vertiv Liebert AL6B0NHVGNNXLKB is a 10kVA/9kW online UPS designed for critical three-phase infrastructure. It accepts 200/100 through 240/120 VAC inputs and delivers clean 208/120 VAC output to protected loads. Lithium-ion batteries provide 8 minutes of runtime at full load. Hot-swappable power, battery and control modules allow maintenance without interrupting connected equipment.

Input Frequency and Voltage Window

The unit auto-senses input frequency between 40 Hz and 70 Hz, accommodating unstable generator or utility sources. A 4-wire L-L-N-G connection is required for installation. Output frequency defaults to 60 Hz and can be user-configured to 50 Hz where needed. Operating temperature range spans 0 °C to 40 °C with humidity tolerance up to 95 % non-condensing. Sites outside these environmental limits will need additional climate control.

Runtime Capacity and Physical Footprint

At full 9 kW load the battery sustains output for 8 minutes; at half load runtime extends to 18 minutes. The rack/tower chassis measures 38 x 17 x 34 inches and weighs 402 lbs, requiring adequate floor or rack space and structural support. Buyers needing longer autonomy at full load or a smaller physical profile should evaluate alternative configurations.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $22,037.99
Pricier than about 95% of the 1,153 comparable items (median $948.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameVertiv
Product lineLiebert
Model nameAL6B0NHVGNNXLKB
Power
Voltage version208 V
AC input voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input line frequency40 Hz to 70 Hz auto-sensing
Power input4-Wire (L-L-N-G)
Volt-ampere rating10kVA
Power rating9 kW
Voltage output200/100, 208/120, 220/110, 230/115, 240/120 VAC
AC output frequency60 Hz default; 50/60 Hz user-configurable
Battery typeLithium Ion
Runtime on batteryFull Load: 8 mins.
Half Load: 18 mins.
Size & build
Product dimensions38 in × 17 in × 34 in
Product weight402 lb (182 kg)
Shipping weight182.34 kg
Package size965 × 965 × 432 mm
Environment & compliance
Temperature rangeOperating temperature: 32 °F - 104 °F (0 °C - 40 °C)
Humidity range0–95%, non-condensing

Other versions of this model

5 more in the same range

Questions about this item

What input voltage configurations does the 10kVA model support?

The unit accepts 200/100, 208/120, 220/110, 230/115, and 240/120 VAC, so you can match the exact service feeding your rack.

What does the 9kW rating mean for connected equipment at full load?

At full load the UPS delivers 9kW for 8 minutes on its lithium-ion battery, giving a brief window for graceful shutdown or generator start.

How does the 4-wire L-L-N-G connection affect installation?

The 4-wire input requires two line conductors, a neutral, and a ground, which is standard for 208/120 V three-phase services in North American data centres.