We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton 9PX6KTF5 6 kVA UPS 18×5-20R 2×L6-20R 1×L6-30R

SKU CH-3Y0Q-F30PB MPN 9PX6KTF5

A 6 kVA battery backup with 18 NEMA 5-20R, two L6-20R, one L6-30R and hardwired outlets, plus USB, RJ-45 and RS-232 management

  • AC input voltage100 V AC to 276 V AC 120 V AC Nominal 200 V AC Nominal 208 V
  • Voltage output120 V AC Nominal 208 V AC Nominal 220 V AC Nominal 230 V AC
  • Power outlets1 x NEMA L6-30R 18 x NEMA 5-20R 2 x NEMA L6-20R Hardwired
  • Runtime on battery0.05 Hour 0.13 Hour
  • Communication portsUSB RJ-45 RS-232 Serial
  • Product weight284
  • 6 kVA capacity protects critical loads
  • 18 NEMA 5-20R and 2 L6-20R outlets power many devices
  • L6-30R plus hardwired input suits rack installs
  • USB, RJ-45 and RS-232 ports enable remote management
  • 05 to 0.13 hour runtime covers short outages

6 kVA UPS with mixed NEMA outlets

The Eaton 9PX6KTF5 is a 6 kVA battery backup designed for server rooms and network closets that need both 120 V and 208–240 V distribution. It accepts an input range of 100 V to 276 V AC and delivers nominal output at 120 V, 208 V, 220 V, 230 V and 240 V AC. The unit provides 18 NEMA 5-20R outlets, two NEMA L6-20R outlets, one NEMA L6-30R outlet and hardwired connections. Management is handled through USB, RJ-45 and RS-232 serial ports.

Replaces smaller single-voltage UPS units

This model replaces lower-capacity UPS hardware that only offers a single output voltage or fewer outlet types. The jump is worth it when equipment racks require simultaneous 120 V and 208–240 V feeds, or when the broader 100 V to 276 V input window improves compatibility with unstable utility power. Battery run times of 0.05 hour and 0.13 hour cover short outages and allow graceful shutdown.

Suits racks needing mixed 120 V and 208–240 V loads

It suits administrators who need dense 5-20R receptacle counts alongside locking L6-20R and L6-30R outlets for higher-draw gear. The 284 weight figure means the unit requires appropriate floor or rack support. Buyers who need extended battery runtime beyond the listed figures, or who require output voltages outside the 120 V to 240 V nominal range, should look at other solutions.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $5,238.99
Pricier than about 90% of the 1,153 comparable items (median $948.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameEATON
Model name9PX6KTF5
Ports & slots
Communication portsUSB
RJ-45
RS-232 Serial
Power
AC input voltage100 V AC to 276 V AC
120 V AC Nominal
200 V AC Nominal
208 V AC Nominal
230 V AC Nominal
240 V AC Nominal
Voltage output120 V AC Nominal
208 V AC Nominal
220 V AC Nominal
230 V AC Nominal
240 V AC Nominal
Power outlets1 x NEMA L6-30R
18 x NEMA 5-20R
2 x NEMA L6-20R
Hardwired
Runtime on battery0.05 Hour
0.13 Hour
Size & build
Shipping weight120.20 kg
Package size965 × 660 × 610 mm

Questions about this item

What clearance and floor capacity are needed for the 284 lb 9PX6KTF5 tower?

The unit weighs 284 lb; place it on a level floor rated for that load and allow front clearance for the 18 NEMA 5-20R, 2 NEMA L6-20R and 1 NEMA L6-30R outlets.

How do I connect the USB, RJ-45 and RS-232 ports for monitoring, and what step is often missed?

Plug the USB cable into the server, connect the RJ-45 to the network for Web/SNMP, attach the RS-232 serial cable if required, then configure the IP address in the management card — skipping the IP setup leaves the card unreachable.

When should the internal battery modules be replaced given the 0.05 h and 0.13 h runtimes?

Runtime of 0.05 hour at full load and 0.13 hour at half load indicates the battery set; plan replacement every 3–5 years or when self-test reports reduced capacity.

More in Uninterruptible Power Supplies (UPS)

Similar items