Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 60 A single-pole molded-case breaker rated 277/480 V AC with 14 kA interrupting capacity and thermal-magnetic trip for bolt-on panelboards
The GE TEY160 is a single-pole molded case circuit breaker rated at 60 A for 277/480 V AC systems with a 14 kA interrupting rating at 277 V AC. It bolts onto GE AE lighting panels and uses a fixed thermal-magnetic trip calibrated to a 250 A instantaneous threshold. Buyers who need multi-pole protection or a higher frame rating cannot use this unit.
The bolt-on panelboard mounting style secures the breaker directly to the panel bus, while the lug terminal accepts standard conductor connections without additional hardware. The 125 A frame size and 1-pole width of 1 in determine the slot space required inside the enclosure. Installers without compatible GE AE panelboards or bolt-on bus arrangements cannot mount this breaker.
The breaker carries a 125 V DC rating alongside its AC rating, but its 14 kA AIR applies only at 277 V AC and does not extend to the full 480 V AC level. The fixed instantaneous trip at 250 A cannot be adjusted for selective coordination schemes. Systems requiring adjustable trips, higher interrupting capacity at 480 V AC, or DC interrupting ratings beyond the stated value fall outside this device's capabilities.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
The thermal-magnetic trip unit is sealed and factory-calibrated; it requires no scheduled maintenance and is replaced only if the breaker trips and will not reset.
The breaker is rated to interrupt up to 14 kA at 277 V AC; sustained faults above that level exceed its tested limit.
Continuous 60 A operation produces normal thermal-magnetic heating within the 125 A frame; the breaker is designed to run at full load without forced cooling.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?