Goodman B1370191 Primary Limit Switch 220 F
Primary limit switch rated for 220 F, new condition, direct from manufacturer
- Primary limit switch cuts power at 220 °F
- Goodman brand ensures OEM fit for HVAC systems
- New condition guarantees full factory performance
- Listed by manufacturer in April 2023
- Part number B1370191 matches original equipment specification
Goodman B1370191 Primary Limit Switch
The Goodman B1370191 is a primary limit switch rated to open at 220 degrees Fahrenheit. It serves as a safety control for HVAC systems found in recreational vehicles. The component interrupts power when temperatures exceed the preset threshold. Installers use it to replace a failed or out-of-calibration original switch.
Replaces a tripped or drifting limit switch
A switch that no longer resets or that opens well below 220 F will shut the furnace down prematurely. Swapping in this new Goodman part restores the correct high-temperature cutoff. The change is worth it when diagnostic tests show the original device is out of specification.
Fits the existing furnace control circuit
The switch mounts in the factory location and connects to the existing wiring harness. No modifications to the bracket or wire length are required. Using the correct OEM rating prevents nuisance lockouts and frees the technician from bypassing safety controls during troubleshooting.
How it compares
Measured against everything we stock in Fans, Vents & Climate Control, at today’s prices. Recalculated every night.
- Price $60.99
- Typical for this category: the median of 328 items is $68.99.
Specifications
| Product | |
|---|---|
| Brand name | GOODMAN |
Questions about this item
What temperature does the Goodman B1370191 primary limit switch trip at?
This safety switch opens the circuit at 220 F to protect the furnace from overheating.
How is the Goodman B1370191 limit switch installed in the furnace?
Mount the switch on the designated bracket in the heat exchanger compartment and connect the two wire leads to the control board terminals.
When should the Goodman B1370191 primary limit switch be replaced?
Replace the switch if the furnace cycles on the high-limit code, if the disc stays open after cooling, or if visual inspection shows discolouration or deformation.
More in Fans, Vents & Climate Control
Similar items
Metra 20" industrial floor fan, 125W
- High velocity, heav…
- 23.82 in (60.5 cm)
Metra 460 Whole Room Air Circulator, 3-Speed, Adjustable Tilt, Black
- Adjustable Tilt, 46…
- 11.25 in (28.6 cm)