We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

MINUTEMAN

MINUTEMAN EC1000LCD 1000VA 900W UPS

SKU CH-T5QV-CQEA7 MPN EC1000LCD

Provides true on-line double-conversion backup with LCD monitoring, six controllable NEMA 5-15R outlets, and hot-swappable battery for critical equipment

  • Voltage version120 V
  • AC input voltage0-160VAC
  • Input line frequency50/60 Hz +/- 6 Hz Auto-sensing
  • Power inputNEMA 5-15P
  • Volt-ampere rating1000 VA
  • Power rating900 W
  • True on-line double-conversion technology provides clean sinewave power
  • LCD display shows real-time status and diagnostics at a glance
  • 9 output power factor delivers 900 W from 1000 VA rating
  • Two controllable outlet banks let you prioritise critical loads
  • Hot-swappable battery replacement without powering down connected equipment

True on-line double-conversion UPS

The Minuteman EC1000LCD is a 1000VA 900W tower UPS that uses true on-line double-conversion technology to regenerate the incoming AC signal. It delivers pure sinewave output at 110V 120V or 127V with a 0.9 output power factor. Six NEMA 5-15R receptacles provide controllable outlet banks for connected equipment. The unit suits critical loads in data centres voice and data communications security systems and light industrial applications.

Thermals noise and power draw

Operating temperature range spans 32 to 104°F (0 to 40°C) while storage reaches 14 to 122°F (-10 to 50°C). Input voltage range covers 0 to 160VAC with auto-sensing 50/60Hz frequency. The 140 joule surge energy rating handles spikes. Economy mode option improves efficiency during normal operation. Battery run time provides 10 minutes at half load and 2 minutes at full load with an 8 hour recharge to 90 percent.

Build fit and expandability

Tower form factor measures 10.2 inches high 6.1 inches wide and 15.9 inches deep. Input connects via NEMA 5-15P plug. A DB-9 serial port enables management through SentryHD software while an optional SNMP card adds network monitoring. Hot-swappable battery replacement uses BM0076 modules. Independent battery bypass maintains voltage regulation and surge protection even with dead or removed batteries. Extended runtime capability supports additional battery packs for longer backup.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $758.99
Cheaper than about 57% of the 1,153 comparable items (median $948.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameMINUTEMAN
Model nameEC1000LCD
Ports & slots
Communication portsDB-9
Power
Voltage version120 V
AC input voltage0-160VAC
Input line frequency50/60 Hz +/- 6 Hz Auto-sensing
Power inputNEMA 5-15P
Volt-ampere rating1000 VA
Power rating900 W
Voltage output120 V
AC output frequency50/60 Hz +/-0.2 Hz unless synchronized to line
Power outlets6
Battery typeSealed Lead Acid
Runtime on batteryHalf Load: 10 min
Full Load: 2 min
Battery charge time8 h to 90% from total discharge
Replacement batteryBM0076
Surge protection rating140 Joules
Size & build
Product dimensions10.2 in × 15.9 in × 6.1 in
Product weight28.2 lb (12.8 kg)
Shipping weight14.06 kg
Package size495 × 375 × 260 mm
Environment & compliance
Regulatory approvalscULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU)
Temperature rangeOperating Temperature +32 to 104 °F (0 to 40 °C)
Storage Temperature +14 to 122 °F (-10 to 50 °C)
Humidity range10% to 90% non-condensing

Other versions of this model

5 more in the same range

Questions about this item

How do I install the EC1000LCD and what step is commonly missed?

Connect the NEMA 5-15P input plug to a 120 V AC branch circuit, attach loads to the six NEMA 5-15R outlets, then configure the two controllable outlet banks via the LCD or SentryHD software; the step often missed is assigning each load to the correct bank so non-critical devices shed first during extended outages.

What maintenance or replacement will the EC1000LCD need later?

The sealed lead-acid battery (part BM0076) is hot-swappable and typically requires replacement every three to five years; recharge takes 8 hours to 90 % after a full discharge, and the independent battery bypass lets the UPS continue surge protection even with the battery removed.

What limit appears first when the EC1000LCD runs continuously at full load?

At 900 W the internal battery provides only 2 minutes of runtime, so battery endurance is the first constraint; the unit also operates between 0 and 40 °C, and sustained full-load operation will approach the thermal limit before the 140-joule surge rating or the 0.9 power factor become factors.