Oakton Instruments pH 700 Meter with Electrode ATC Probe Stand
Benchtop pH meter covering 0.00–14.00 with automatic temperature compensation up to 100 °C, supplied with a double-junction refillable glass electrode, ATC probe and stand
- Product typeEnvironmental & Mechanical
- pH range 0.00 to 14.00 covers full scale
- automatic temperature compensation adjusts readings from 0 to 100 °C
- double-junction refillable glass electrode simplifies maintenance
- probe stand keeps sensor stable during use
- three-year manufacturer warranty protects your investment
Oakton pH 700 benchtop meter
The Oakton pH 700 is a benchtop instrument designed for laboratory pH measurement across the full 0.00 to 14.00 range. It ships as a complete kit that includes a double-junction refillable glass electrode, an automatic temperature compensation probe and a dedicated probe stand for stable positioning during use.
Thermals noise and power in normal use
The meter operates without active cooling, so it produces no fan noise and draws minimal power from its supply during routine measurements. Automatic temperature compensation adjusts readings across the 0 to 100 degrees Celsius displayed range without adding measurable heat or acoustic output to the bench environment.
Included electrode probe and stand benefits
The double-junction refillable glass electrode extends service life by allowing electrolyte replacement when reference junction performance declines. The ATC probe enables temperature-corrected results without manual calculation, while the supplied stand holds both probes securely to prevent tip damage and ensure consistent immersion depth during testing.
How it compares
Measured against everything we stock in Test Equipment & Meters, at today’s prices. Recalculated every night.
- Price $667.99
- Pricier than about 90% of the 202 comparable items (median $148.99).
Specifications
| Product | |
|---|---|
| Brand name | OAKTON |
| Product type | Environmental & Mechanical |
Questions about this item
How do I install the double-junction refillable glass pH electrode and ATC probe on the pH 700 meter?
Connect the electrode BNC and ATC phono plugs to the front panel, seat the probe in the stand, remove the protective cap, and fill the reference chamber with fresh KCl solution before first use.
What maintenance or replacement will the double-junction refillable glass pH electrode need later?
Refill the reference chamber with KCl solution regularly, rinse the glass bulb with distilled water after each use, and replace the electrode when calibration slope falls below acceptable limits.
What limit appears first during sustained use of the pH 700 meter?
The electrode response slows as the reference junction clogs, and the meter reads only up to 100 Degrees C, so temperature compensation stops above that point.
More in Test Equipment & Meters