We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Protects single-phase branch circuits up to 20 A with a Z-curve thermal-magnetic trip and 14 kA interrupting rating at 120/240 V AC
The Schneider Electric C60BP is a single-pole miniature circuit breaker rated at 20 A with a Z-curve thermal-magnetic trip. It is designed for branch-circuit protection on DIN-rail panels where precise, fast tripping safeguards sensitive electronic loads. The unit carries a UL 489 listing and a 14 kA interrupting rating at 120/240 V AC.
The Z-curve response trips between 2 and 3 times the rated current, providing tighter overload discrimination than standard B or C curves. This behaviour reduces nuisance tripping on circuits with high inrush while still clearing faults quickly enough to protect semiconductor devices and control transformers. No additional accessories or software are bundled with the breaker itself.
The breaker handles AC systems up to 480 V and DC circuits up to 60 V, with a 63 A frame size that gives headroom for co-ordination studies. Screw-clamp terminals accept conductors from 18 AWG to 8 AWG, allowing straightforward installation in compact panels. It is not suited for multi-pole applications or for loads that require a higher interrupting capacity than 14 kA.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Schneider Electric |
| Product type | Circuit Breakers |
The thermal-magnetic trip unit is sealed for the life of the breaker and the screw-clamp terminals accept 18 to 8 AWG conductors without ongoing maintenance.
The interrupting rating is 14 kA at 120/240 V AC, so sustained fault currents above that level would exceed the breaker's limit.
Normal operation at 20 A produces modest heat; the 0.71 in wide housing is designed for DIN-rail mounting with standard enclosure ventilation.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?