We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 60 A, three-pole molded-case breaker with a 65 kA interrupting rating at 240 V AC for I-Line panelboards
The SQUARE D HGA36060 is a molded-case circuit breaker rated at 60 amps with three poles for three-phase AC systems. It mounts on I-Line panelboards and uses a thermal-magnetic trip mechanism with fixed instantaneous settings. This unit suits industrial control panels and power distribution boards requiring a 150A frame size.
The breaker carries an AC voltage rating of 600V and a maximum AIR rating of 65kA at 240V AC. Its DC voltage rating is 250V DC. These ratings define the highest system voltage and available fault current the device can safely interrupt. Applications exceeding either value require a different protection class.
The trip unit offers a high amp setting of 450A and a low amp setting of 800A with no adjustment range. This fixed curve determines the exact overcurrent response for motor starts and short-circuit events. Installers must verify that these non-adjustable thresholds match the coordination study for the panel.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SQUARE D |
This breaker is a fixed 60 A, 3-pole unit in the PowerPact H frame rated 150 A. Choose it when the circuit requires exactly 60 A three-phase protection; otherwise select a different ampere rating within the same frame.
It means the breaker can safely interrupt fault currents up to 65 kA on a 240 V AC system. Your available short-circuit current must not exceed this value at the point of installation.
The I-Line mounting uses plug-on bus connections instead of bolt-on lugs. It fits only Square D I-Line panelboards; it will not mount in standard bolt-on or DIN-rail enclosures.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?