We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv Liebert GXT5-1000LVRT2UXL UPS 1000VA/1000W 120V 2U

SKU CH-GMFT-1M6V5 MPN GXT5-1000LVRT2UXL

Online double-conversion UPS delivers 1000VA/1000W with zero transfer time, six NEMA 5-15R outlets and 17.9 minutes runtime at half load

  • Voltage version120 V
  • AC input voltage60-150 V
  • Input line frequency40-70 Hz; Auto Sensing
  • Power inputNEMA 5-15P
  • Volt-ampere rating1000 VA
  • Power rating1000 W
  • Online double-conversion topology delivers zero transfer time
  • Unity power factor provides 1000 W from 1000 VA rating
  • Six NEMA 5-15R outlets support multiple devices
  • 2U rack/tower form factor fits 3.4 in height
  • VRLA battery yields 17.9 min at half load

Vertiv GXT5 1000VA Online UPS

The Vertiv Liebert GXT5-1000LVRT2UXL is a double-conversion online UPS rated at 1000VA and 1000W. It accepts 120V input from 60-150V at 40-70Hz and delivers user-configurable output at 110/115/120/125VAC with +/-3% regulation. Six NEMA 5-15R outlets connect via a NEMA 5-15P plug with a 10 ft cord. The 2U rack-tower chassis measures 3.4" x 16.9" x 15.7" and weighs 37 lbs.

Suits mission-critical IT equipment needing zero

IT managers protecting servers, network gear or storage arrays gain continuous power conditioning and battery backup with VRLA cells. Half-load runtime reaches 17.9 minutes while full load provides 6.7 minutes. The unit operates from 32°F to 104°F and stores from -4°F to 140°F in 0-95% non-condensing humidity. UL 1778 4th Edition and CSA 22.2 No 107.3 approvals apply. Buyers needing more than six outlets, alternative receptacle types or longer battery runtime at full load should consider other solutions.

1000W double-conversion capacity decides fit

The single specification that determines suitability is the 1000W output rating combined with online double-conversion topology. If the connected load exceeds 1000W or the application can tolerate standby or line-interactive designs, this unit is not the right match.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $993.99
Typical for this category: the median of 1,153 items is $948.99.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameVertiv
Product lineLiebert
Model nameGXT5-1000LVRT2UXL
Power
Voltage version120 V
AC input voltage60-150 V
Input line frequency40-70 Hz; Auto Sensing
Power inputNEMA 5-15P
Volt-ampere rating1000 VA
Power rating1000 W
Voltage output110/115/120/125VAC; (user-configurable); +/-3%
Power outlets6
Battery typeValve Regulated Lead Acid (VRLA)
Runtime on batteryHalf Load: 17.9 min
Full Load: 6.7 min
Size & build
Product dimensions3.4 in × 16.9 in × 15.7 in
Product weight37 lb (16.8 kg)
Shipping weight22.63 kg
Package size617 × 569 × 262 mm
Environment & compliance
Regulatory approvalsUL 1778 4th Edition and CSA 22.2 No 107.3
Temperature rangeOperating Temperature: 32 °F - 104 °F (0°-40°)
Storage Temperature: -4 °F - 140 °F (-20°-60°)
Humidity range0% to 95%, non-condensing

Questions about this item

Does the UPS require a NEMA 5-15R wall outlet for its input plug?

Yes, the unit ships with a NEMA 5-15P plug on a 10 ft cord, so a matching NEMA 5-15R receptacle rated for 120 V is required for the input connection.

Will the six NEMA 5-15R outlets power legacy servers that draw up to 1000 W total?

The UPS delivers 1000 W continuous across all six NEMA 5-15R receptacles, supporting legacy loads up to that combined wattage with 0 ns transfer time on battery.

How can I confirm the UPS is regulating voltage within the +/-3 % spec after installation?

Use the colour graphic LCD to view real-time output voltage; it should read between 110 V and 125 V depending on the user-configured setting, indicating regulation is active.

More in Uninterruptible Power Supplies (UPS)

Similar items