We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 15 ft 50 A generator cord with STW 6/3+8/1 cable, N14-50P plug, bare-wire end, IP44 rating and -40 °F to 140 °F operating range
This 15 ft cord carries 50 A at 110 V for up to 12500 W. It uses a 6/3+8/1 gauge STW cable with pure copper conductors and an N14-50P plug terminating in bare wire for hard-wired connections. The IP44 rating and -40 °F to 140 °F temperature range suit outdoor generator hook-ups for homes, offices or workshops.
The moulded N14-50P plug features an ergonomic grip that eases insertion and removal from a generator receptacle. A supplied storage strap keeps the heavy 6 AWG cable coiled neatly when not in use. The STW jacket resists moisture, oil and UV exposure, so the cord stays flexible in cold weather and does not degrade in sunlight.
Confirm the generator provides a matching N14-50R receptacle rated for 50 A at 125/250 V before ordering. The bare-wire end requires termination inside a transfer switch, inlet box or panel by a qualified electrician following local codes. Ensure the installation location stays within the 15 ft reach and that the IP44 splash rating meets the site conditions.
Measured against everything we stock in AC Extension Cords, at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Product type | Other Appliances |
Check that the generator output matches 125V or 250V and the load does not exceed 12500W; the UL listing and STW 6/3+8/1 construction confirm the 50A capacity when used within those limits.
The box contains one 15 ft N14-50P to bare-wire extension cord and one storage strap; a SS2-50R or other 50A receptacle for the bare wires must be purchased separately.
The 15 ft length suits most generator-to-panel runs; select a longer cord only if the distance exceeds 15 ft, keeping voltage drop in mind for the 6 AWG conductors.
More in AC Extension Cords
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?