CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Provides 410 W battery backup with four NEMA 5-15R outlets plus USB-A and USB-C ports for charging devices
The APC BVK750M2 is a 750 VA / 410 W tower UPS designed to keep a desktop PC, external hard drive and wireless router running during a brief outage. It plugs into a standard 120 V NEMA 5-15P wall socket and supplies power through four NEMA 5-15R receptacles. USB Type-A and Type-C ports let you manage the unit from a connected computer.
Output is a stepped approximated sine wave at 60 Hz, which is adequate for typical PC power supplies and networking gear but not for sensitive medical or precision equipment. At the full 410 W rating the battery lasts about 1.97 minutes, while a 205 W half load extends runtime to roughly 9.7 minutes. Recharge takes six hours after a full discharge.
The 410 W limit means you cannot run a high-end GPU workstation or multiple monitors plus a laser printer simultaneously. Surge protection is rated at 350 joules and includes RJ-45 dataline shielding for a router or modem. Battery is user-replaceable, so the unit can return to service after the cells wear out.
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Power | |
|---|---|
| Runtime on battery | At full load (410 W): Approximately 1.97 minutes At half load (205 W): Approximately 9.7 minutes |
| Size & build | |
| Shipping weight | 6.62 kg |
| Package size | 445 × 241 × 203 mm |
Size the load by watts; the unit delivers up to 410 W continuously, while 750 VA is the apparent-power rating.
At 410 W the battery lasts about 1.97 minutes; at a typical 205 W load you gain roughly 9.7 minutes to save work and shut down.
It provides a data link for power-management software so the computer can trigger an orderly shutdown when battery runs low.
More in Uninterruptible Power Supplies (UPS)
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?