CyberPower PR1000LCD 1000VA 1000W Mini-Tower UPS
Pure sine-wave battery backup delivers 1000 VA and 1000 W with eight NEMA 5-15R outlets, automatic voltage regulation and an extendable LCD panel
- Voltage version120 V
- AC input voltage75–154 V
- Input line frequency47 Hz - 63 Hz (auto-sensing)
- Power inputNEMA 5-15P
- Volt-ampere rating1000 VA
- Power rating1000 W
Model PR1000LCD
- Pure sine wave output protects sensitive electronics with 1000W capacity
- 8 NEMA 5-15R outlets plus USB and serial ports connect all gear
- Automatic voltage regulation corrects brownouts and overvoltages from 75 to 154V
- Extendable LCD panel shows runtime and load status at a glance
- 5 minutes runtime at half load keeps systems running through outages
Pure Sine Wave UPS for Sensitive Electronics
The CyberPower PR1000LCD delivers 1000VA and 1000W of pure sine wave output from a mini-tower chassis. Eight NEMA 5-15R outlets provide battery backup and surge protection for workstations, networking gear or home-office servers. An extendable LCD panel shows real-time status while RS-232 and USB ports enable management via PowerPanel Business Edition software. It suits users who need clean power for active PFC power supplies.
Replacing Simulated Sine Wave or Standby Units
A jump to this line-interactive UPS is worthwhile when equipment requires pure sine wave output to prevent shutdowns or audible noise during battery transfer. Full AVR buck/boost corrects brownouts and overvoltages between 75 and 154V without draining the battery. The 1030 joule surge rating guards connected hardware from transient spikes. GreenPower UPS topology reduces energy consumption during normal operation.
Straightforward Setup with Replaceable Battery
Installation consists of connecting the NEMA 5-15P input plug and attaching equipment to the eight rear outlets. The sealed lead-acid battery is user-replaceable using part number RB12120X2A after roughly three to five years. Recharge takes three hours in quick-charge mode or eight hours in eco mode. Common issues include forgetting to enable the EPO port loop or overlooking the RS-232 cable when configuring network management cards.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $619.99
- Cheaper than about 62% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | CyberPower |
| Product line | Smart App Sinewave |
| Model name | PR1000LCD |
| Ports & slots | |
| Communication ports | RS-232, USB |
| Power | |
| Voltage version | 120 V |
| AC input voltage | 75–154 V |
| Input line frequency | 47 Hz - 63 Hz (auto-sensing) |
| Power input | NEMA 5-15P |
| Volt-ampere rating | 1000 VA |
| Power rating | 1000 W |
| Voltage output | On Battery Voltage: 120 Vac +/-5% |
| Power outlets | 8 |
| Battery type | Sealed Lead Acid |
| Runtime on battery | Runtime at Half Load (min): 24.5 Runtime at Full Load (min): 7 |
| Battery charge time | 3 h - Quick Charge Mode, 8 h - Eco Mode |
| Replacement battery | RB12120 × 2A |
| Alerts | On Battery, Low Battery, Overload, Fault |
| Surge protection rating | 1030 Joules |
| Size & build | |
| Product dimensions | 8.7 in × 17 in × 6.7 in (H × W × D) |
| Product weight | 44 lb (20 kg) |
| Shipping weight | 21.82 kg |
| Package size | 572 × 353 × 318 mm |
| In the box | |
| In the box | 79210R |
| Environment & compliance | |
| Regulatory approvals | UL1778, cUL 107.3, FCC DOC Class A, RoHS |
| Software | |
| Control software | PowerPanel Business Edition |
Other versions of this model
5 more in the same range
CyberPower PR2200LCDSL 2070VA 1980W 120V UPS
- 120 V
- 75Vac - 154Vac +/-…
CyberPower PR1500LCDN UPS 1500VA/1500W 120V 8 Outlets
- 120 VAC
- 47–63 Hz
CyberPower PR3000LCDSL 3000VA 2700W UPS
- 120 V
- 75Vac - 154Vac +/-…
Questions about this item
Will the NEMA 5-15P input plug fit a standard 120 V wall outlet without an adapter?
Yes, the NEMA 5-15P input connects directly to a standard 120 V wall outlet; no adapter is required for the 75-154 V input range.
What is the correct order for connecting the USB or RS-232 cable to enable PowerPanel Business Edition monitoring?
Install PowerPanel Business Edition first, then connect the USB or RS-232 cable to the PC; the software will detect the UPS and configure automatic shutdown settings.
Which user-replaceable battery pack restores the original 24.5-minute half-load runtime when the sealed lead-acid cells wear out?
Order the RB12120X2A replacement cartridge; it is the exact sealed lead-acid pack specified for this unit and restores factory runtime.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
APC SMC1500-2UC 1440 VA 900 W 6 Outlets Pure Sinewave UPS
- 120 V
- 106–130 V
Tripp Lite BP48VRM2U 48V EBM for 750/1000/1500VA SmartPro UPS
- 1 Year
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P










