We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

MINUTEMAN

MINUTEMAN PRO1000RT2U UPS 1000VA 700W 2U Rack Tower 8x NEMA 5-15R

SKU CH-CPRQ-J6N8K MPN PRO1000RT2U

Line-interactive UPS delivers 1000VA and 700W with eight NEMA 5-15R outlets and 960 joules surge protection in a 2U rack or tower form

  • Voltage version120 V
  • AC input voltage90–150 V
  • Input line frequency60 Hz +/-6 Hz
  • Power inputNEMA 5-15P
  • Power rating700 W
  • Voltage output103 to 136VAC
  • Runs up to 15 minutes at half load on sealed lead-acid battery
  • Protects connected gear with 960 joules surge suppression and RJ11/RJ45/coax filtering
  • Fits standard racks in a 2U, 3.4-inch high chassis with tower or wall-mount option
  • Delivers regulated 103-136 VAC output from 90-150 VAC input via automatic voltage regulation
  • Powers eight NEMA 5-15R outlets from a single NEMA 5-15P plug

1000VA rack tower UPS for servers

The Minuteman PRO1000RT2U is a line-interactive uninterruptible power supply rated at 1000VA and 700W. It accepts 120V input from a NEMA 5-15P plug and delivers regulated 120V output through eight NEMA 5-15R receptacles. The 2U form factor suits rack, tower or wall mounting in network closets or server rooms.

2U metal chassis with data-line protection

A sealed lead-acid battery provides up to 15 minutes of run time at half load and 5 minutes at full load. Surge protection is rated at 960 joules and covers RJ11, RJ45 and coaxial connections alongside the AC outlets. The unit operates from 0 to 40 degrees Celsius and stores from -15 to 45 degrees Celsius in humidity up to 95 percent non-condensing. Approvals include cTUVus, CE, RoHS2 and FCC Part 15 Class B.

Check 120V supply and outlet count

Verify that your facility provides 120V AC service within the 90 to 150V input window and 60Hz frequency. Ensure the NEMA 5-15P input plug matches your branch circuit and that eight NEMA 5-15R outlets are sufficient for the connected equipment. Confirm the 3.4 by 16.1 by 18.9 inch dimensions fit your rack or shelf space before ordering.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $422.99
Cheaper than about 69% of the 1,153 comparable items (median $948.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameMINUTEMAN
Model namePRO1000RT2U
Ports & slots
Protected data linesRJ11 / RJ45 and Coax
Power
Voltage version120 V
AC input voltage90–150 V
Input line frequency60 Hz +/-6 Hz
Power inputNEMA 5-15P
Power rating700 W
Voltage output103 to 136VAC
AC output frequency60 Hz +/- 6 Hz
Power outlets8
Battery typeSealed, non-spillable, maintenance free, valve regulated lead acid
Runtime on battery5 min Half Load, 15 min Full Load
Surge protection rating960 Joules
Size & build
Rack mountingYes
Product dimensions3.4 in × 16.1 in × 18.9 in
Product weight35.7 lb (16.2 kg)
Shipping weight19.05 kg
Package size584 × 559 × 254 mm
Environment & compliance
Regulatory approvalscTUVus (Meets UL1778 and CSA 22.2), CE, RoHS2 and FCC Susceptibility Part 15 Class B
Temperature rangeOperation (storage): 0° to 40 °C / +32° to 104 °F (-15° to 45 °C / +5° to 113 °F)
Humidity rangeOperation (Storage): 5 to 95% non-condensing

Other versions of this model

5 more in the same range

Questions about this item

Does the NEMA 5-15P input limit the UPS to a 15 A branch circuit?

Yes, the NEMA 5-15P plug connects to a standard 120 V 15 A circuit, and the input voltage range is 90 to 150 V at 60 Hz.

What physical space is required to mount the 2U chassis in a rack?

The unit measures 3.4 inches high, 16.1 inches wide and 18.9 inches deep, fitting a standard 2U rack opening.

How do you install the battery module, and what step is commonly missed?

Remove the front panel, slide the battery tray out, connect the internal battery leads, then re-secure the tray and panel; the step often missed is firmly seating the connector before sliding the tray back.

More in Uninterruptible Power Supplies (UPS)

Similar items