MINUTEMAN ED2000RTXL2UNC 2000VA 1800W 2U UPS
2U double-conversion UPS delivers 2000VA/1800W with 120V output, eight 5-15/20R plus one L5-20R receptacles, and 12-minute half-load runtime
- Voltage version120 V
- AC input voltage0-160VAC
- Input line frequency50/60 Hz +/- 6 Hz Auto-sensing
- Power inputNEMA 5-20P
- Volt-ampere rating2000 VA
- Power rating1800 W
- True on-line double conversion protects critical loads
- 2U rack height fits dense server cabinets
- 9 output power factor delivers 1800 W from 2000 VA
- LCD display shows status at a glance
- Three controllable load banks extend runtime for priority gear
2U On-Line UPS for Dense Racks
The Minuteman Endeavor ED2000RTXL2UNC is a 2000VA 1800W double-conversion unit in a 2U chassis. It suits server rooms and network closets where clean 120V output and flexible mounting matter. True on-line topology isolates connected gear from every input anomaly. The 0.9 output power factor supports modern power supplies efficiently.
Replaces Line-Interactive Units When Uptime Is
Step up from line-interactive models when equipment cannot tolerate any transfer time or voltage distortion. The jump is worth it for loads that demand continuous sine-wave output through brownouts, sags and frequency drift. Input range of 0-160VAC handles severe utility swings without draining the battery. Selectable 110VAC output accommodates legacy hardware.
Four Minutes at Full Load Then Eight-Hour Recharge
At 1800W the sealed lead-acid pack delivers four minutes of run time; half load extends this to twelve minutes. Recharge to 90 percent takes eight hours from total discharge. Economy mode reduces losses during stable utility conditions. Three controllable load banks let administrators shed non-critical outlets to extend backup for essential devices.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $1,788.99
- Pricier than about 71% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | MINUTEMAN |
| Product line | ENDEAVOR |
| Model name | ED2000RTXL2UNC |
| Power | |
| Voltage version | 120 V |
| AC input voltage | 0-160VAC |
| Input line frequency | 50/60 Hz +/- 6 Hz Auto-sensing |
| Power input | NEMA 5-20P |
| Volt-ampere rating | 2000 VA |
| Power rating | 1800 W |
| Voltage output | 120VAC, User selectable: 110VAC |
| AC output frequency | 50/60 Hz +/- 0.5 Hz unless synchronized to line |
| Power outlets | 9 |
| Battery type | Sealed Lead Acid |
| Runtime on battery | Half Load: 12 min Full Load: 4 min |
| Battery charge time | 8 h to 90% from total discharge |
| Replacement battery | BM0037 |
| Surge protection rating | 1000 Joules |
| Size & build | |
| Product dimensions | 3.5 in × 19 in × 17 in |
| Product weight | 47.6 lb (21.6 kg) |
| Shipping weight | 25.86 kg |
| Package size | 597 × 549 × 224 mm |
| Environment & compliance | |
| Regulatory approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU) |
| Temperature range | Operating Temperature: +32 to 104 °F (0 to 40 °C) Storage Temperature: +5 to 113 °F (-15 to 45 °C) |
| Humidity range | 95% non-condensing |
Other versions of this model
5 more in the same range
MINUTEMAN ED-3KTF UPS 3KVA 208-240V In 120V Out
- 208 V
- 208–240 V
MINUTEMAN ED-5KTF UPS 5KVA 208-240V In 120V Out
- 208 V
- 208–240 V
MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable
- 120 V
- 0-160VAC
Questions about this item
What rack space and wall-mount kit does the 2U UPS need?
The unit occupies 2U of rack height, measures 19 inches wide and 3.5 inches high, and rackmount ears come attached; an optional install kit is required for wall mounting.
Which input plug and circuit are required for the 2000VA model?
Connect the NEMA 5-20P input to a 120 V AC, 20 A branch circuit; the UPS auto-senses 50/60 Hz input frequency.
When and how do I replace the internal battery?
Replace the sealed lead-acid battery (part BM0037) when runtime drops below the 12-minute half-load or 4-minute full-load figures; allow 8 hours to reach 90 % charge after installation.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
Tripp Lite SmartPro SM3000RMXLNTAA UPS 3000VA 2250W 120V 2U
- 120 V AC
- NEMA L5-30P
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC