We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv PSI5-1500RT120TAA UPS 1500VA 1350W 120V

SKU CH-7FD0-T7XPK MPN PSI5-1500RT120TAA

Line-interactive UPS delivers 1500VA/1350W with pure sine wave output, AVR, rotatable LCD and hot-swappable batteries

  • Voltage version120 V
  • AC input voltage75 to 146 VAC
  • Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
  • Power inputNEMA 5-15
  • Volt-ampere rating1500 VA
  • Power rating1350 W
  • 1500 VA capacity supports critical loads
  • Pure sine wave output protects sensitive equipment
  • Automatic voltage regulation corrects 75 to 146 VAC input
  • Hot-swappable battery enables replacement without downtime
  • 1372 joule surge rating shields connected devices

1500VA TAA-compliant UPS

The Vertiv PSI5-1500RT120TAA is a line-interactive battery backup rated at 1500VA and 1350W with a .9 power factor. It accepts 120V input through a NEMA 5-15 plug and provides six NEMA 5-15R outlets. The rotatable LCD monitor simplifies status checks in tower or rack orientation.

Pure sine wave on battery with AVR

Automatic voltage regulation corrects sags and swells between 75 and 146 VAC without using battery capacity. When the supply fails, the inverter delivers a pure sine wave output to protect sensitive loads. At full load the VRLA batteries sustain operation for 6 minutes; at half load the runtime extends to 18 minutes. Recharge to 90 percent takes 4 hours.

Hot-swappable batteries replace aging cells

The internal VRLA pack is rated for a 5-year life and can be swapped without powering down connected equipment. This unit replaces smaller VA backups that lack AVR or pure sine wave output, and it upgrades installations that need network management via the RJ-45 port. It is not suited for loads exceeding 1350W or for environments outside 32 to 104°F operating temperature.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $886.99
Typical for this category: the median of 1,153 items is $948.99.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameVertiv
Product lineLiebert
Model namePSI5-1500RT120TAA
Power
Voltage version120 V
AC input voltage75 to 146 VAC
Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
Power inputNEMA 5-15
Volt-ampere rating1500 VA
Power rating1350 W
Voltage output120 V
Power outlets6
Battery typeValve Regulated Lead Acid (VRLA)
Runtime on batteryFull Load: 6 min
Half Load: 18 min
Battery charge time4 h to recover 90%
Surge protection rating1372 Joules
Size & build
Product dimensions3.5 in × 17.2 in × 20 in
Product weight42.6 lb (19.3 kg)
Shipping weight23.50 kg
Package size670 × 575 × 260 mm
Environment & compliance
Regulatory approvalsUL 1778, c-UL-us Listed
Temperature rangeOperating Temperature: 32° to 104 °F (0° to 40 °C)
Storage Temperature: 5° to 120 °F (-15° to 50 °C)
Humidity range20% - 90%, non-condensing

Other versions of this model

5 more in the same range

Questions about this item

How much heat does the 1500VA UPS add to a rack that operates continuously at full load?

At full load the unit draws 1350W and its operating temperature range is 32° to 104°F, so the waste heat stays within that envelope; the rotatable LCD lets you monitor internal temperature without opening the rack.

What input plug and outlet types must already be present in the rack or wall circuit for this UPS to work?

The UPS connects with a NEMA 5-15 input plug and provides six NEMA 5-15R outlets, so the site needs a standard 120V 15A receptacle and matching cords for the protected equipment.

Will the USB and network management card work with older servers that only have serial or PS/2 management ports?

This model includes USB and an RJ-45 network port but no serial or PS/2 ports, so legacy servers would need a USB-to-serial adapter or network-based management software to communicate with the UPS.

More in Uninterruptible Power Supplies (UPS)

Similar items