Vertiv PSI5-3000RT120TAA UPS 2880VA 2700W 120V TAA 2U Rack/Tower
Line-interactive UPS delivers 2880 VA and 2700 W with pure sine-wave output, 0.9 power factor, rotatable LCD and 2U rack/tower form factor
- Voltage version120 V
- AC input voltage75 to 146 VAC
- Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
- Power inputNEMA L5-30P
- Volt-ampere rating2880 VA
- Power rating2700 W
Model PSI5-3000RT120TAA
- Pure sine wave output protects sensitive equipment on battery
- 9 power factor delivers 2700 W from 2880 VA rating
- Rotatable LCD monitor stays readable in rack or tower orientation
- Hot-swappable VRLA battery enables replacement without downtime
- 1372 joule surge rating shields connected loads from transients
2880 VA 2700 W line-interactive UPS
This Vertiv Liebert PSI5 unit delivers 2880 VA and 2700 W of pure sine-wave backup power with a 0.9 power factor. It accepts 120 V input through a NEMA L5-30P plug and provides seven outlets including NEMA 5-15/20R, 5-20R and L5-30R types. The rotatable LCD monitor suits both rack and tower orientations.
Input range 75 to 146 VAC with AVR
Automatic voltage regulation corrects sags and swells between 75 and 146 VAC without using the battery, preserving runtime for true outages. Frequency tolerance spans 55 to 65 Hz with a 57 to 63 Hz window for battery-to-normal return. Surge protection is rated at 1372 joules. Operating temperature range is 32 to 104°F.
Replaces smaller VA units when runtime matters
At full load the VRLA battery provides 5.5 minutes of runtime; at half load it extends to 16 minutes. Recharge to 90 percent takes four hours. Hot-swappable battery modules allow replacement without powering down connected equipment. Buyers needing longer runtime at full load or higher VA capacity will need a larger UPS.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $1,612.99
- Pricier than about 68% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Vertiv |
| Product line | Liebert |
| Model name | PSI5-3000RT120TAA |
| Power | |
| Voltage version | 120 V |
| AC input voltage | 75 to 146 VAC |
| Input line frequency | 55 to 65 Hz (57 to 63 Hz Battery to Normal comeback) |
| Power input | NEMA L5-30P |
| Volt-ampere rating | 2880 VA |
| Power rating | 2700 W |
| Voltage output | 120 V |
| Power outlets | 7 |
| Battery type | Valve Regulated Lead Acid (VRLA) |
| Runtime on battery | Full Load: 5.5 min Half Load: 16 min |
| Battery charge time | 4 h to recover 90% |
| Surge protection rating | 1372 Joules |
| Size & build | |
| Product dimensions | 3.5 in × 17.2 in × 24.8 in |
| Product weight | 70.8 lb (32.1 kg) |
| Shipping weight | 37.10 kg |
| Package size | 775 × 575 × 263 mm |
| Environment & compliance | |
| Regulatory approvals | UL 1778, c-UL-us Listed |
| Temperature range | Operating Temperature: 32° to 104 °F (0° to 40 °C) Storage Temperature: 5° to 120 °F (-15° to 50 °C) |
| Humidity range | 20% - 90%, non-condensing |
Other versions of this model
5 more in the same range
Vertiv PSI5-1500RT120TAAN UPS 1500VA 1350W 120V TAA Line-Interactive Tower/Rack Network Card
- 120 V
- 75 to 146 VAC
Vertiv PSI5-2200RT120TAA UPS 1920VA 1920W 120V TAA
- 120 V
- 75 to 146 VAC
Vertiv PSI5-2200RT120TAAN UPS 1920VA 1920W 120V TAA Tower/Rack
- 120 V
- 75 to 146 VAC
Vertiv PSI5-3000RT120TAAN UPS 2880VA 2700W 120V Tower/Rack with Network Card
- 120 V
- 75 to 146 VAC
Questions about this item
Should I pick the 2880 VA / 2700 W model or a lower-capacity unit for my rack?
Choose the 2880 VA model when your connected load approaches 2700 W; it delivers 5.5 minutes at full load and 16 minutes at half load, while smaller units would exhaust runtime sooner.
What does the 2700 W rating mean once the UPS is installed and powering equipment?
It is the maximum real power the inverter can supply continuously; at that level the battery lasts 5.5 minutes, dropping to 16 minutes if the actual draw is roughly half of 2700 W.
The input uses a NEMA L5-30P plug — what does that cap in practice?
The L5-30P connection limits the UPS to a 30 A, 120 V branch circuit, so the 2880 VA rating cannot be exceeded without upgrading the supply circuit.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
CyberPower PR3000RT2UCN UPS 3000VA 3000W 100-120V NEMA L5-30P 2U Rack Tower 9 Outlets
- 120 V
- 75–149 VAC
Eaton 5P1500R-L 1440 VA 1100W Lithium-ion UPS
- 120 V default (100/…
- 89-151 Vac (adjusta…
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P