Vertiv PSI5-2200RT120TAAN UPS 1920VA 1920W 120V TAA Tower/Rack
Tower/rack UPS delivers 1920 VA pure sine-wave power with automatic voltage regulation and an installed network card for remote management
- Voltage version120 V
- AC input voltage75 to 146 VAC
- Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
- Power inputNEMA L5-20 std 5-20 adapter included
- Volt-ampere rating1920 VA
- Power rating1920 W
Model PSI5-2200RT120TAAN
- Pure sine wave output protects sensitive equipment
- Unity power factor delivers full 1920W from 1920VA rating
- Automatic voltage regulation corrects 75 to 146VAC input without battery drain
- Rotatable LCD monitor readable in tower or rack orientation
- Network management card installed enables remote monitoring and control
1920VA 120V Tower/Rack UPS
The Vertiv PSI5-2200RT120TAAN is a 1920VA 1920W uninterruptible power supply for 120V environments. It delivers pure sine wave output on battery and includes an installed IS-UNITY-SNMP network card for remote monitoring. The unit operates as a tower or in a rack mount with a rotatable LCD monitor. TAA compliance suits federal and regulated projects.
Upgrade from standby or line-interactive units
Replaces basic standby UPS models that pass utility power directly and only switch to battery during outages. The jump is worth it when connected equipment requires pure sine wave output and automatic voltage regulation across a 75 to 146 VAC input range. The 0.9 power factor supports modern power supplies more efficiently than older designs.
Check your 120V infrastructure first
Verify the site provides a 120V circuit with a NEMA L5-20 receptacle or a 5-20 outlet for the included adapter. Confirm rack space of 3.5 inches height and 24.8 inches depth for the 59.1 lb unit. Ensure operating temperatures stay between 32°F and 104°F with 20 to 90 percent non-condensing humidity.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $1,602.99
- Pricier than about 68% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Vertiv |
| Product line | Liebert |
| Model name | PSI5-2200RT120TAAN |
| Power | |
| Voltage version | 120 V |
| AC input voltage | 75 to 146 VAC |
| Input line frequency | 55 to 65 Hz (57 to 63 Hz Battery to Normal comeback) |
| Power input | NEMA L5-20 std 5-20 adapter included |
| Volt-ampere rating | 1920 VA |
| Power rating | 1920 W |
| Voltage output | 120 V |
| Power outlets | 7 |
| Battery type | Valve Regulated Lead Acid (VRLA) |
| Runtime on battery | Full Load: 5 min Half Load: 14 min |
| Battery charge time | 4 h to recover 90% |
| Surge protection rating | 1372 Joules |
| Size & build | |
| Product dimensions | 3.5 in × 17.2 in × 24.8 in |
| Product weight | 59.1 lb (26.8 kg) |
| Shipping weight | 26.81 kg |
| Package size | 630 × 437 × 89 mm |
| In the box | |
| In the box | With SNMP Card |
| Environment & compliance | |
| Regulatory approvals | UL 1778, c-UL-us Listed |
| Temperature range | Operating Temperature: 32° to 104 °F (0° to 40 °C) Storage Temperature: 5° to 120 °F (-15° to 50 °C) |
| Humidity range | 20% - 90%, non-condensing |
Other versions of this model
5 more in the same range
Vertiv PSI5-1500RT120TAAN UPS 1500VA 1350W 120V TAA Line-Interactive Tower/Rack Network Card
- 120 V
- 75 to 146 VAC
Vertiv PSI5-2200RT120TAA UPS 1920VA 1920W 120V TAA
- 120 V
- 75 to 146 VAC
Vertiv PSI5-3000RT120TAA UPS 2880VA 2700W 120V TAA 2U Rack/Tower
- 120 V
- 75 to 146 VAC
Vertiv PSI5-3000RT120TAAN UPS 2880VA 2700W 120V Tower/Rack with Network Card
- 120 V
- 75 to 146 VAC
Questions about this item
What rack height does the 3.5" tall PSI5-2200RT120TAAN require?
The unit is 3.5 inches high, which equals a standard 2U rack space, and includes mounting ears for 19-inch racks.
How do I connect the NEMA L5-20 input to a regular 5-20 receptacle?
Use the included 5-20 adapter; plug the UPS into the adapter first, then into the wall outlet — skipping the adapter is the common mistake.
When should I replace the Valve Regulated Lead Acid batteries?
Expect 3–5 years service life; replace when runtime drops noticeably below the 5-minute full-load or 14-minute half-load figures.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
APC SMT1500RM2UCUS UPS 1500VA 2U Rackmount 120V
- Run time Half Load…
- RJ-45, USB, Smart-S…
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC