Vertiv PSI5-5000RT208 UPS 5000VA 4250VA 3825W 208V 2U Rack/Tower
Line-interactive UPS delivers 4250 VA and 3825 W from a 2U rack or tower chassis with four NEMA L6-30R outlets and a four-hour recharge
- Voltage version208 V
- AC input voltage150-281VAC
- Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
- Power inputNEMA L6-30P
- Volt-ampere rating4250 VA
- Power rating3825 W
- 0 minutes runtime at full load protects critical equipment
- 0 minutes runtime at half load extends availability
- 4 hour recharge to 90% restores backup quickly
- 2U rack/tower form factor fits dense installations
- 2064 joules surge energy rating shields connected devices
What this UPS delivers
The Vertiv PSI5-5000RT208 is a line-interactive UPS rated at 5000 VA and 3825 W with a 208 V AC input and output. It fits a 2U rack or tower footprint and provides four NEMA L6-30R outlets for connected equipment. The unit is suited for server rooms and network closets that require battery backup with hot-swappable modules and an LCD status display.
Installation checks
Verify that your facility supplies 208 V AC through a NEMA L6-30P plug and that the input voltage stays within the 150-281 VAC range. Confirm the rack or tower space can accommodate a 2U high unit measuring 3.5 by 17.2 by 24.8 inches and weighing 87.7 lbs. Ensure the operating environment remains between 32 and 104 °F with humidity from 20 to 90 percent non-condensing.
Sustained-load behaviour
At full load the battery provides 3.0 minutes of run time, extending to 10.0 minutes at half load. After a discharge the internal VRLA batteries recharge to 90 percent capacity in four hours. Surge protection is rated at 2064 joules and the unit carries UL 1778 and c-UL-us listings for continuous operation.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $4,156.99
- Pricier than about 88% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Liebert |
| Product line | PSI5 |
| Model name | PSI5-5000RT208 |
| Power | |
| Voltage version | 208 V |
| AC input voltage | 150-281VAC |
| Input line frequency | 55 to 65 Hz (57 to 63 Hz Battery to Normal comeback) |
| Power input | NEMA L6-30P |
| Volt-ampere rating | 4250 VA |
| Power rating | 3825 W |
| Voltage output | 208VAC (100/110/115/125 VAC TDU Required) |
| Power outlets | 4 |
| Battery type | Valve Regulated Lead Acid (VRLA) |
| Runtime on battery | Full Load: 3.0 min Half Load: 10.0 min |
| Battery charge time | 4 h to recover 90% |
| Replacement battery | PSI5-72VBATT |
| Surge protection rating | 2064 Joules |
| Size & build | |
| Rack mounting | 2U Rack/Tower |
| Product dimensions | 3.5 in × 17.2 in × 24.8 in |
| Product weight | 87.7 lb (39.8 kg) |
| Shipping weight | 44.82 kg |
| Package size | 678 × 551 × 259 mm |
| Environment & compliance | |
| Regulatory approvals | UL 1778, c-UL-us Listed |
| Temperature range | Operating Temperature: 32°-104 °F (0°-40 °C) Storage Temperature: 5°-120 °F (-15° - 50 °C) |
| Humidity range | 20% to 90% non-condensing |
Other versions of this model
5 more in the same range
Vertiv PSI5-1500RM1201U UPS 1440VA 1350W 120V 1U
- 120 V
- 75-146VAC
Vertiv PSI5-800RT120N 800VA 720W Line-Interactive UPS 2U Rack/Tower
- 120 V
- 75-146VAC
Vertiv PSI5-3000RT120 UPS 2880VA 2700W 120V 2U Rack/Tower
- 120 V
- 75-146VAC
Questions about this item
What comes in the box with the PSI5-5000RT208 and what must be purchased separately for 120V equipment?
The unit ships with a 2U rack/tower chassis, internal VRLA batteries, an LCD status display, an RJ-45 network port and four NEMA L6-30R outlets. A step-down transformer is required to power 100, 110, 115 or 125 VAC loads.
Which battery module is the correct replacement for this UPS?
The hot-swappable replacement cartridge is the PSI5-72VBATT, designed for tool-less exchange while the UPS remains online.
How long will the UPS sustain my 3825 W load during a mains failure?
At the full 3825 W rating the internal batteries provide 3.0 minutes of runtime; at half load the runtime extends to 10.0 minutes.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
Vertiv GXT5-6KL630RT5UXLN UPS 4900VA 4600W 208V 2xC19 6xC13 Hardwired 205kg
- 208 V AC
- 2 x IEC 60320 C19,…
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P
Eaton SU6000RTFMB 6000VA UPS 230V In Multi-Out
- 230 V AC
- 100 V AC, 110 V AC,…