Vertiv PSI5-800RT120N 800VA 720W Line-Interactive UPS 2U Rack/Tower
Line-interactive UPS delivers 800 VA and 720 W with automatic voltage regulation and six NEMA 5-15R outlets in a 2U rack/tower form factor
- Voltage version120 V
- AC input voltage75-146VAC
- Input line frequency55 to 65 Hz (57 to 63 Hz Battery to Normal comeback)
- Power inputNEMA 5-15
- Volt-ampere rating800 VA
- Power rating720 W
- 800VA 720W capacity protects critical electronics during outages
- 0 minutes half-load runtime allows orderly shutdown
- 5 minutes full-load runtime safeguards high-demand equipment
- 2U rack/tower design fits diverse installation spaces
- 1372 joules surge rating shields connected devices from spikes
Ideal for edge deployments
The Vertiv PSI5-800RT120N is a line-interactive UPS rated at 800VA and 720W, built for 120V environments. It protects active PFC power supplies, conventional power supplies, networking gear, workstations and point-of-sale systems in media closets or small racks. Six NEMA 5-15R outlets and a rotating LCD give clear status in either rack or tower orientation.
Upgrade from basic surge strips
This unit adds automatic voltage regulation across a 75-146VAC input window and pure battery backup with 5.5 minutes at full load or 16 minutes at half load. The jump is worthwhile when equipment needs orderly shutdown time or when voltage sags and swells exceed what a strip can absorb. It is not suited for loads that exceed 720W or for installations requiring extended runtime beyond the internal battery.
Simple 2U rack or tower setup
The 2U convertible chassis mounts in standard racks or sits as a tower with the display rotated. A hot-swappable battery cartridge (PSI5-24VBATT) reaches 90% charge in four hours. The only common pitfall is forgetting to configure the output voltage (100/110/115/125VAC) to match the connected gear before powering on.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $1,224.99
- Pricier than about 58% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Liebert |
| Product line | PSI5 |
| Model name | PSI5-800RT120N |
| Power | |
| Voltage version | 120 V |
| AC input voltage | 75-146VAC |
| Input line frequency | 55 to 65 Hz (57 to 63 Hz Battery to Normal comeback) |
| Power input | NEMA 5-15 |
| Volt-ampere rating | 800 VA |
| Power rating | 720 W |
| Voltage output | 120VAC (100/110/115/125VAC user-configurable) |
| Power outlets | 6 |
| Battery type | Valve Regulated Lead Acid (VRLA) |
| Runtime on battery | Full Load: 5.5 min Half Load: 16.0 min |
| Battery charge time | 4 h to recover 90% |
| Replacement battery | PSI5-24VBATT |
| Surge protection rating | 1372 Joules |
| Size & build | |
| Rack mounting | 2U Rack/Tower |
| Product dimensions | 3.5 in × 17.2 in × 16.1 in |
| Product weight | 28.4 lb (12.9 kg) |
| Shipping weight | 18.60 kg |
| Package size | 1364 × 1364 × 1364 mm |
| In the box | |
| In the box | With RDU120 Network Card |
| Environment & compliance | |
| Regulatory approvals | UL 1778, c-UL-us Listed |
| Temperature range | Operating Temperature: 32°-104 °F (0°-40 °C) Storage Temperature: 5°-120 °F (-15° - 50 °C) |
| Humidity range | 20% to 90% non-condensing |
Other versions of this model
5 more in the same range
Vertiv PSI5-1500RM1201U UPS 1440VA 1350W 120V 1U
- 120 V
- 75-146VAC
Vertiv PSI5-3000RT120 UPS 2880VA 2700W 120V 2U Rack/Tower
- 120 V
- 75-146VAC
Vertiv PSI5-5000RT208 UPS 5000VA 4250VA 3825W 208V 2U Rack/Tower
- 208 V
- 150-281VAC
Questions about this item
What rack depth does the 2U rack/tower chassis require for mounting?
The unit is a 2U rack/tower convertible design; allow standard 2U vertical space and ensure the rack depth accommodates the chassis length with clearance for rear cable connections.
How do I configure the output voltage to match my equipment?
Use the front-panel LCD menu to select 100, 110, 115, 120 or 125 VAC before connecting loads; the default is 120 VAC and the setting is retained after power cycles.
Which replacement battery kit restores runtime when the internal cells age?
Order the PSI5-24VBATT kit; recharge takes four hours to reach 90 % capacity and typical half-load runtime is 16 minutes with fresh batteries.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
Eaton 5P3000 3000VA 2700W Tower UPS 7 Outlets
- 100 V AC Nominal/Ad…
- 3000 VA
APC SURTA1500RMXL2U 1500VA 1050W 2U Rack Tower UPS
- 90–150 V
- 50/60 Hz +/- 5 Hz (…
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P
Eaton 9SX1500 1500VA 1350W UPS 6 Outlets
- 60 Hz: 50-70 Hz, 50…
- 5-15P